Single Use Sterile Intubation Stylet Rigid Stylets Anesthesia Instruments 25 Pcs

Single Use Sterile Intubation Stylet Rigid Stylets Anesthesia Instruments 25 Pcs
Single Use Sterile Intubation Stylet Rigid Stylets Anesthesia Instruments 25 Pcs
Single Use Sterile Intubation Stylet Rigid Stylets Anesthesia Instruments 25 Pcs

Single Use Sterile Intubation Stylet Rigid Stylets Anesthesia Instruments 25 Pcs

Single Use Sterile Intubation Stylet Rigid Stylets Anesthesia Instruments 25 Pieces Box. Intubation Health Care Single Use Sterile Intubation Stylet is a cost-effective solution for healthcare providers and patients. Its single-use design reduces cross-contamination and infections, while its rigid construction ensures proper endotracheal tube placement. The sterile packaging saves time and eliminates cleaning, sterilization, and assembly. The stylet's consistent quality and reliability reduce maintenance and associated costs, making it a valuable tool in clinical settings.

SINGLE USE: Designed for single-use, minimising the risk of cross-contamination and ensuring patient safety. STERILE: Packaged sterile to maintain high hygiene standards and ready for immediate use. PLASTIC COMPOSITE HANDLE: Durable and easy to handle, providing a secure grip during intubation.

RIGID DESIGN: Provides shape and rigidity to the endotracheal tube, ensuring proper placement and minimizing trauma to the patient's airway. EASY EXTRACTION: Equipped with a thumb tab for partial removal, softening the tube tip to pass smoothly through the vocal cords. STANDARD LENGTH: Overall length of 360mm (14.17?) with a working length of 266mm (10.47?), suitable for various intubation needs.

BALL SIZE: 5mm ball size, ensuring compatibility with standard endotracheal tubes. CONVENIENT PACKAGING: Box contains 25 pieces, each individually packaged for convenience and efficiency.

Load the endotracheal tube onto the single-use intubation stylet, ensuring the distal end of the stylet does not extend beyond the distal end of the ET tube. Position the ET tube at the opening of the vocal cords, avoiding advancement of the stylet past the vocal cords.

Once the ET tube is engaged in the glottic, openings, extract the stylet (5 cm) using the thumb tab. This softens the tip, allowing the tube to pass through the vocal cords. Position the ET tube as per standard practice.

Remove the stylet from the ET tube. Are you looking for something similar?
Single Use Sterile Intubation Stylet Rigid Stylets Anesthesia Instruments 25 Pcs


Index  Links  Contact  Privacy Policies  Service Agreement